Skip to content
Workshop: repairs and experiments

Power and batteries

A DIY car jump starter: Li-ion 3S, LiFePO4 4S and supercapacitors

10.11.2026

How much current the starter of a 1.3 to 6 L engine draws, and why a start takes seconds, not minutes. A Li-ion 3S jump pack with USB-C charging: cells, "C" rating, contactor, diodes, controller and code. A LiFePO4 4S pack with a 200 A BMS that pre-charges a flat battery and helps start the car. Whether you can do without a lead-acid battery, Li-ion or LiFePO4, supercapacitors.

Article with a tool

A DIY 8S 280 Ah LiFePO4 battery: assembly, BMS, temperature sensors and compression

10.11.2026

Building a 24 V LiFePO4 battery from eight EVE 280 Ah cells: checking and top-balancing the cells, busbars and insulation, what a JBD BMS can do and which thresholds to set, where to put the three temperature sensors, and whether to compress the cells — and why not with clamps.

APC Smart-UPS 1000 and 1500 on an 8S LiFePO4 battery: wiring, COM port setup, cooling

10.11.2026

How to fit 8S LiFePO4 to an SUA1000I and SUA1500I: BMS, wires and Anderson connectors, a separate charger, pack count and voltmeter calibration over the COM port, cold start, a fan with a thermal switch, capacitors and the full command list.

APC Smart-UPS 1500 and 1000: an FT232RL COM adapter, because USB cannot calibrate

09.11.2026

Which APC Smart-UPS commands work over the COM port, USB and the AP9617 network card, where values come with tenths and hundredths, three adapter wirings (FT232RL + MAX3232, or two NPN or PNP transistors) with a COM port bracket, 5 V or 3.3 V, and telling several UPSes apart by serial number.

Flashing an IMAX B6 clone (ATmega32A) with cheali-charger via USBASP

14.04.2017

How to reflash a Chinese IMAX B6 charger clone with the open-source cheali-charger firmware: the USBASP driver, ISP wiring, a factory firmware backup, writing, calibration and going back.

APC Smart-UPS 1000 on car batteries: battery calibration

13.02.2016

An APC SUA1000I with two 45 Ah Varta batteries thought they were flat. A home-made 940-0024C COM cable, constant 0 = FF in a service tool, and a calibration: 250 W for over three hours.